Scheduled monitoring and log retention
Two periodic tasks keep Outbridge monitoring useful: one evaluates alert rules, the other keeps execution history and logs to an agreed size. Both are found under Modules > Outbridge > Periodic.
Alert monitoring #
Periodic > Alert monitoring evaluates every enabled alert rule in the current legal entity, opens or updates incidents for breached conditions, resolves incidents whose condition has cleared, and queues alert email.
Schedule it as a recurring batch job. Choose a recurrence no longer than the shortest Window used by your rules—a rule with a 10-minute window evaluated once an hour will miss short breaches and report stale observations.
The job's Infolog summarizes each run: how many rules were evaluated, and how many incidents were opened, updated, resolved, or skipped for insufficient data. A second line summarizes the alert email queue, including any configuration problems that left email pending.
You can also start this job from the action pane of the Alert rules form using Schedule alert monitoring, and review previous runs with Batch job history.
Alert monitoring only reads execution history. It never changes an integration, and it never runs a port.
Log cleanup #
Periodic > Log cleanup deletes execution history, detailed log entries, and retained snapshots that have aged past their retention period.
The dialog takes:
- Execution history retention (days)—how long execution records are kept.
- Detailed log retention (days)—how long individual log entries are kept. Set this shorter than the execution history retention to keep the run history browsable while discarding its verbose detail.
- Maximum records per cleanup transaction—how many records are removed per transaction. Lower values make cleanup gentler on a busy environment; higher values finish sooner. The value must be greater than zero.
The dialog also offers a standard query, so cleanup can be restricted—for example to one port whose history has grown unusually large.
Snapshot retention is separate and is configured with Snapshot retention (days) in Outbridge parameters, together with Save snapshots and Snapshot data type, which decide whether a snapshot is captured at all.
Schedule log cleanup as a recurring batch job. Run it outside your integration windows: cleanup and integration processing compete for the same tables.
If cleanup cannot delete a particular execution or its detailed logs, it reports that correlation in the Infolog and continues with the rest. A repeatedly reported correlation usually belongs to an execution that never reached a terminal status; review it in run history.
Process ports #
Periodic > Process ports is the batch task that runs data ports on a schedule, and is documented with the file based integration guides. It is listed here because it appears in the same menu and in the Scheduled runs list of the Outbridge operations workspace, where you can review and change its recurrence alongside the monitoring jobs.