Operational alert rules

An operational alert rule defines a condition over Outbridge execution history. When scheduled monitoring finds the condition breached, it opens an operational incident and, if the rule has notification targets, queues an email.

To configure alert rules, in Finance and Operations, go to Modules > Outbridge > Setup > Alert rules.

Create a rule #

  1. Select New.
  2. Enter a Rule name. The name must be unique.
  3. Complete the General tab as described below.
  4. Add recipients on the Alert targets tab if the rule should send email.
  5. Select Preview to evaluate the rule against current data without creating an incident.
  6. Select the Enabled check box to include the rule in scheduled monitoring.
  7. Select Save.

General #

Scope #

  • Execution target type—All, Port, or Port group. Choose All to evaluate every observed target independently.
  • Execution target—the specific port or port group the rule monitors. It must be blank when the target type is All.
  • Execution scope—Root runs only evaluates top-level executions; Include nested runs also counts runs nested inside port groups. Root runs only is the right choice for most rules, because a failing port group would otherwise be counted twice.

Condition #

  • Evaluation type—Fixed threshold compares the metric with a value you enter. Percentage change compares the metric with the preceding period of the same length.
  • Metric—one of:
  • Records processed—records successfully processed.
  • Failed executions—the count of failed executions.
  • Execution failure rate—failed executions as a percentage of eligible executions.
  • Error log entries—the number of error entries logged.
  • Average duration—average execution duration in seconds.
  • Comparison—derived from the evaluation type and metric, and shown read-only. Fixed-threshold rules use greater than or equal to or less than or equal to; percentage-change rules use percentage increase or percentage decrease.
  • Window—the period ending at evaluation time: 10 minutes, 30 minutes, 1 hour, 4 hours, 12 hours, 24 hours, or 7 days. Percentage-change rules compare this window with the preceding window of the same length.
  • Trigger value—the metric value for fixed-threshold rules. For percentage-change rules, enter the percentage: 50 means 50%. The value cannot be negative.
  • Minimum samples—the minimum number of eligible executions required before rates, averages, and trends are evaluated. Rates, averages, and trends require at least 1. Below this count the rule reports Insufficient data instead of breaching, which stops a single overnight run from raising a false alarm.
  • Severity—Information, Warning, or Error. Severity is recorded on the incidents the rule creates. It does not affect evaluation or which recipients are notified.
  • Condition—a read-only summary of the metric, comparison, trigger value, window, and minimum sample requirement, so you can confirm the rule reads the way you intended.

A Records processed threshold requires a specific port or port group. A "records processed dropped below X" rule is meaningless across all targets at once, so the rule is rejected when the target type is All.

Alert targets #

Each row nominates one recipient for the rule's email notifications.

  • Recipient type—User or User group.
  • Recipient—the Finance and Operations user, or the user group whose enabled members receive the email.

A nominated user must exist, be enabled, and have a valid email address. For a user group, every enabled member with a valid email address is notified.

Before a rule with notification targets can be enabled, a valid Alert email template must be selected in Outbridge parameters. A rule with no targets still opens incidents; it simply does not send email.

Preview #

Preview evaluates the selected rule immediately against current data and reports one of:

  • Healthy—the condition is not breached.
  • Breached—the condition is breached. The preview shows the observed value, the baseline value, and the sample count.
  • Insufficient data—there were fewer eligible executions than Minimum samples, or no eligible execution target exists in the current window.

Preview does not create, update, or resolve incidents, and does not send email. Use it to tune the trigger value and minimum samples before enabling a rule.

Scheduling evaluation #

Schedule alert monitoring in the action pane schedules the evaluation batch job for every enabled rule in the current legal entity. Batch job history opens the standard batch job history for that job. See Scheduled monitoring and log retention.

Disabling and deleting #

Clearing Enabled removes the rule from scheduled monitoring. Existing incidents are kept and remain visible.

A rule that already has incident history cannot be deleted; disable it instead. This preserves the audit trail behind incidents that were raised in the past.

Alert rules through OData #

Alert rules and their targets are exposed as the OSTDBMetricAlertRules and OSTDBMetricAlertTargets data entities, so rule definitions can be deployed between environments alongside the rest of the Outbridge configuration.